₹ 30000 / Piece Get Latest Price
| Test Method | Electrochemical |
| Equipment Type | Non Destructive Test |
| Application Area | Construction |
| Material Tested | Concrete |
| Usage | Lab and Field |
| Resistance Values | 10 Mohms |
| Test Standard | ASTM |
| Usage/Application | Measurement and Test Equipment |
| I am interested in | DC Voltage |
| Coating Type | Paint |
| Automation Grade | Automatic |
| Power Source | Battery |
| Brand | Titan |
| Industry Served | Construction, Oil And Gas |
| Exposure Duration | Above 1000 Hrs |
| Body Material | Plastic |
| Temperature Range | 50–70°C |
| NABL Accreditation | Yes |
| Temperature | 50 Degree |
| Service Mode | Onsite Testing |
| Portability | Portable |
| Ip Rating | IP67 |
| Material | ABS |
Minimum order quantity: 1 Piece
Titan HC Pro – Half Cell Potentiometer | Corrosion Testing Equipment | ASTM C876 & IS-516 Compliant
Corrosion is a natural process that occurs when a structure is exposed to elements like CO2 or chloride, which can penetrate the concrete all the way to the steel reinforcement. This can have serious durability and safety consequences, which is why it is important to monitor corrosion using an accurate and trusted method. The half-cell potential test is the only corrosion monitoring technique standardized in ASTM C876 – 15 & IS-516. Titan Engineering Equipments is a leading manufacturer of India for half cell potentiometer, delivering precision-engineered solutions like Titan HC Pro for reliable corrosion assessment.
Purpose of Half Cell Potential Test:
To detect whether corrosion activity of the steel reinforcement is actively occurring.
To assess the probability of corrosion in the steel reinforcement.
To locate corrosion prone areas across the concrete surface
Monitor the effectiveness of protection measures.
| High |
Factors influencing half cell potential test:
a) Concrete Moisture Content: The amount of moisture in concrete significantly affects half-cell potential readings. Dry concrete can produce less negative (more positive) potentials, giving the false impression of low corrosion risk, whereas properly moist concrete provides more accurate readings.
b) Type, Condition, and Coverage of Steel Reinforcement: The nature of the steel, its coating (if any), and the thickness of the concrete cover influence potential measurements. Well-protected or deeply embedded steel may show less negative potential even when corrosion is present.
c) Temperature and Environmental Conditions: Temperature variations and environmental factors such as humidity can alter the electrochemical behavior of steel and concrete, affecting potential readings.
d) Surface Preparation and Contaminants: Proper surface cleaning is necessary for good electrical contact. Dust, chlorides, or other surface contaminants can interfere with electrode connection and distort results.
Various Name: Half cell Potential, Half cell Potential Test, Half Cell Potential Measurement, Half Cell Potentiometer, Half Cell Potential Meter, Corrosion Potential Concrete, Rebar Corrosion Potential, Concrete Reinforcement Corrosion Test, Corrosion Activity in Reinforced Concrete, ASTM C876 (standard for half-cell potentials), Corrosion Monitoring, Half Cell Potential Test, Concrete Corrosion Testing Equipment, Rebar Corrosion Testing Equipment, Concrete Corrosion Assessment, Half Cell Corrosion Testing Meter, Portable Half Cell Tester, Corrosion Potential Measurement Device, Concrete Half Cell Corrosion Measurement, Rebar Corrosion Detection, Rebar Corrosion Evaluation Device.
About Titan HC Pro:
Manufactured by Titan Engineering Equipments, a leading manufacturer of India for half cell potentiometer, Titan HC Pro is a precision-engineered corrosion testing instrument built for accuracy, durability, and ease of use. Compliant with ASTM C876 and IS-516, it delivers reliable half-cell potential measurements for reinforced concrete structures in both field and laboratory conditions.
Our Presence – Domestic Supply (India):
As a leading manufacturer of India for half cell potentiometer, Titan Engineering Equipments has supplied Titan HC Pro across Mumbai, Pune, Nashik, Aurangabad, Surat, Vadodara, Ahmedabad, Indore, Bhopal, Nagpur, Jaipur, Ludhiana, Ghaziabad, Delhi, Lucknow, Kanpur, Prayagraj, Patna, Ranchi, Dhanbad, Bengaluru, Hyderabad, Chennai, Coimbatore, Madurai, Visakhapatnam, Kolkata, and Srinagar.
₹ 7500 / Piece Get Latest Price
| Measuring Range | 0–1250 µm |
| Resolution | 0.1 µm |
| Probe Type | Built In |
| Display Type | LCD |
| Accuracy | ±(1–3)% rdg |
| Data Interface | USB |
| Memory | 1000 Readings |
| Power Source | AAA Battery |
| Substrate Type | F And NF |
Minimum order quantity: 1 Piece
The UNI-T UT343D Coating Thickness Gauge is a compact, reliable, and easy-to-use instrument designed for non-destructive measurement of coating thickness on metal substrates. It is widely used for quality control, inspection, and maintenance applications where accurate paint or coating thickness measurement is required.
The UT343D supports both Ferrous (Fe) and Non-Ferrous (NFe) base materials, making it suitable for measuring coatings such as paint, varnish, enamel, epoxy, powder coating, plating, and galvanization on steel, iron, aluminum, copper, brass, and similar metals.
Key FeaturesAutomatic substrate recognition (Ferrous & Non-Ferrous)
Non-destructive coating thickness measurement
High accuracy with fast response time
Compact, handheld design with clear digital display
Simple one-button operation
Ideal for field and shop-floor inspections
Measurement Range: 0 – 1250 µm
Resolution: 0.1 µm / 1 µm (auto)
Accuracy: ±(3% + 1 µm)
Substrate Type:
Ferrous (Steel, Iron)
Non-Ferrous (Aluminum, Copper, Brass, etc.)
Measurement Principle:
Magnetic induction (Fe)
Eddy current (NFe)
Display: Digital LCD
Power Supply: Battery operated
Operating Temperature: 0°C to 40°C
Paint thickness measurement on steel and aluminum surfaces
Wall paint thickness measurement on metal plaster channels, steel frames, and metal sheets
Automotive refinishing and inspection
Structural steel and fabrication shops
Powder coating and galvanizing inspection
Maintenance and corrosion protection monitoring
No damage to surface or coating
Suitable for on-site inspection
Lightweight and portable
Cost-effective solution for routine coating checks
UNI-T UT343D Coating Thickness Gauge
Standard calibration foils
User manual
Carry pouch
Warranty: Manufacturer standard warranty
₹ 17000 / Piece Get Latest Price
| Measuring Range | 300 mm |
| Resolution | 0.01 mm |
| Probe Frequency | 5 MHz |
| Accuracy | 0.5 % |
| Power Supply | 3 x 1.5V AA batteries |
| Material Mode | Steel |
| Data Interface | No Interface |
| Display Type | Colour Display |
| Battery Life | 6 hrs |
| Brand | Titan |
| Display | 6 digit display |
| Model Name / Number | T100 |
| Least Count | 0.1 mm |
Minimum order quantity: 1 Piece
Ultrasonic Thickness Gauge – Digital Thickness Measurement Instrument
Product Description:
The Ultrasonic Thickness Gauge is a high-precision non-destructive testing (NDT) instrument designed to measure the wall thickness of metal, steel, pipes, tanks, glass, and other solid materials from one side only. It uses the principle of ultrasonic pulse-echo to determine thickness instantly and accurately — even when access is limited to one surface.
Ideal for quality inspection, corrosion monitoring, and maintenance across industries like fabrication, shipbuilding, oil & gas, power plants, and mechanical workshops, this gauge ensures fast, reliable, and repeatable measurements.
Key Features:
Wide measuring range: 1.2 mm to 300 mm (depending on material and probe)
High accuracy ±(0.5% + 0.1 mm) with automatic calibration
Digital LCD display with backlight for field visibility
Multiple modes: Normal, Minimum capture, and Differential
Data storage and USB output for report generation (in select models)
Works with a variety of transducers (2 MHz to 10 MHz) for different materials
Compact, lightweight, and battery-operated for portable use
Auto power-off and low battery indicator
Applications:
Measurement of metal wall thickness in pipelines, pressure vessels, and tanks
Corrosion monitoring in refineries and power plants
Fabrication and welding inspection
Quality assurance in production lines
Thickness testing of aluminium, brass, glass, and plastics
Jitesh Devidas Thorat (CEO)
Titan Engineering Equipments
Nineteen Floor, Bldg No2 Flat No 1903, Swarajya Heights A Wing Chsl, Unnat Nagar, Goregaon West, Near Goregaon Traffic Division
Mumbai - 400104, Maharashtra, India